vmware整套实施项目文档(包含vmware安装配置,emc存储安装配置,emc光纤交换配置,...

您所在的位置:网站首页 emc 存储SE机 vmware整套实施项目文档(包含vmware安装配置,emc存储安装配置,emc光纤交换配置,...

vmware整套实施项目文档(包含vmware安装配置,emc存储安装配置,emc光纤交换配置,...

2024-07-07 19:04| 来源: 网络整理| 查看: 265

Technorati标签: 包含vmware安装配置, emc存储安装配置, emc光纤交换配置, emcvplex本地容灾安装配置及emcDomaindata消重备份安装配置, usbservice安装配置

目录

1.安装ESXi.5

1.1.安装ESXi5.1.5

1.2.配置ESXi5.1.7

2.VMwarevsphereclient的安装...9

3.vCenterServerAppliance5.1安装...12

4.创建数据中心...19

5.Windows2008R2系统安装...29

6.网络配置...32

6.1.开启vmotion.32

6.2.使用端口组...33

7.创建系统模板:...34

7.1.创建模板...34

7.2.从模板部署虚拟机...34

8.EMC存储配置...38

8.1.前期准备...38

8.2.配置storagepool.39

8.3.创建Lun.40

8.4.HBA卡在存储的注册状态...41

8.5.创建StorageGroup.42

9.VPLEXLocal实施...44

9.1.实施计划...44

9.2.VPLEXLocal管理IP配置...44

9.3.VPLEX的SANSwitch配置...44

9.4.创建MetaVolume.47

9.5.VPLEXLocal配置...48

9.6.VPLEX用户管理...58

9.7.登录VPLEXWeb图形管理界面...59

10.VPLEX配置...60

10.1.配置storage加入到vplex.60

10.2.命令行claim新识别的lun.62

10.3.创建extend.63

10.4.创建device.65

10.5.注册主机...69

10.6.创建storageview.70

10.7.创建mirror,实现不同storage之间的数据冗余...77

11.DataDomain实施及配置...79

11.1.DataDoamin设备初始化...79

11.1.1.硬件初始化...79

11.1.2.DDOS初始化...79

11.2.DataDomainCIFS配置...82

11.2.1.登录DD640.82

11.2.2.启动CIFS服务...83

12.AnywhereUSB配置...89

12.1.初始化配置...89

12.2.使用方法...91

1.安装ESXi

下面将进行ESXi主机的安装以及配置,请准备好安装光盘:“VMware-VMvisor-Installer-5.1.0.update01-1065491.x86_64.iso”

1.1.安装ESXi5.1

clip_p_w_picpath002

Step1:插入ESXi安装光盘,服务器BIOS设置从光盘启动,选择“ESXi-5.1.0-20130402001-standardInstaller”

clip_p_w_picpath004

Step2:按下(Enter)

clip_p_w_picpath006

Step3:按下(F11)同意并继续

clip_p_w_picpath008

Step4:选择本地磁盘,按下(Enter)

clip_p_w_picpath010

Step5:按下(Enter)

clip_p_w_picpath012

Step6:输入Root密码,按下(Enter)

clip_p_w_picpath014

Step7:按下(F11)开始安装

clip_p_w_picpath016

Step8:ESXi主机安装完毕,Enter重启刀片服务器。

1.2.配置ESXi5.1

clip_p_w_picpath018

Step1:按下F2,进入配置模式

clip_p_w_picpath020

Step2:输入root密码后按【Enter】

clip_p_w_picpath022

Step3:选择“ConfigureManagenentNetwork”选项

clip_p_w_picpath024

Step4:选择“IPConfigration”

clip_p_w_picpath026

Step5:选择“SetstaticIPaddressandnetworkconfiguration:”选项,输入IP、掩码、网关信息,选择(Enter)

clip_p_w_picpath028

Step6:选择”Yes”选项,保存配置;

2.VMwarevsphereclient的安装

clip_p_w_picpath030

Step1:双击安装文件VMware-viclient.exe或者在vCenterServer安装弹出界面中

点击vSphereClient,在点击安装。

clip_p_w_picpath032

Step2:选择“简体中文”,点击“确定”

clip_p_w_picpath034

Step3:点击“下一步”

clip_p_w_picpath036

Step4:点击“下一步”

clip_p_w_picpath038

Step5:选择“我同意许可协议中的条款”,点击“下一步”

clip_p_w_picpath040

Step6:选择安装路径,点击“下一步”

clip_p_w_picpath042

Step7:点击“安装”

clip_p_w_picpath044

Step8:“VMwarevSphereClient5.1”安装完成

3.vCenterServerAppliance5.1安装

clip_p_w_picpath046

Step1:登陆其中一台ESXi主机,点击“文件”,点击“部署OVF模板”

clip_p_w_picpath048

Step2:点击“浏览”,选择“vCenterServerAppliance5.1.0”,点击“下一步”

clip_p_w_picpath050

Step3:点击“下一步”

clip_p_w_picpath052

Step4:点击“下一步”

clip_p_w_picpath054

Step5:点击“下一步”

clip_p_w_picpath056

Step6:点击“下一步”

clip_p_w_picpath058

Step7:点击“下一步”

clip_p_w_picpath060

Step8:选择该虚拟机放置的存储,点击“下一步”

clip_p_w_picpath062

Step9:使用“ThinProvision”,点击“下一步”,导入完成后开启虚拟机。

clip_p_w_picpath064

Step10:没有DHCP的环境中,需要先配置IP地址,选择“Login”

用户名:root,密码:********

clip_p_w_picpath066

Step11:使用命令配置IP地址:ifconfigeth0**********。再使用ifconfig检验IP地址,输入exit退出。

clip_p_w_picpath068

Step12:查看访问的IP地址及端口,在浏览器中输出该地址。

clip_p_w_picpath070

Step13:输入用户名及密码,点击“Login”

clip_p_w_picpath072

Step14:勾上“Acceptlicenseagreement”,点击“Next”。

clip_p_w_picpath074

Step15:选择“Configurewithdefaultsettings”,点击“Next”。

clip_p_w_picpath076

Step16:点击“Start”。

clip_p_w_picpath078

Step17:选择“Network”,选择“Address”,将DHCP下拉选择静态。

clip_p_w_picpath080

Step18:更改IP地址信息,点击“SaveSettings”进行保存。

4.创建数据中心

clip_p_w_picpath082

Step1:运行“VMwarevSphereClient”,输入vCenterIP、用户名、密码,点击“登录”

clip_p_w_picpath084

Step2:右键选择“新建数据中心”

clip_p_w_picpath086

Step3:改名为“SCCDataCenter”

clip_p_w_picpath088

Step4:在““SCCDataCenter”右键“新建群集”

clip_p_w_picpath090

Step5:名称改为“SCC_HA”,勾选“打开vShpereHA”以及“打开vShpereDRS”,点击“下一步”

clip_p_w_picpath092

Step6:选择“全自动”选项,点击“下一步”

clip_p_w_picpath094

Step7:选择“关闭”选项,点击“下一步”

clip_p_w_picpath096

Step8:选择“启用主机监控”等选项,点击“下一步”

clip_p_w_picpath098

Step9:优先级选择“中等”,主机响应选择“保持打开电源”,点击“下一步”

clip_p_w_picpath100

Step10:虚拟机监控选择“仅虚拟机监控”,点击“下一步”

clip_p_w_picpath102

Step11:勾选“禁用EVC”选项,点击“下一步”

clip_p_w_picpath104

Step12:选择“将交换文件存储相同目录中”,点击“下一步”

clip_p_w_picpath106

Step13:点击“完成”

clip_p_w_picpath108

Step14:右键选择“添加主机”选项

clip_p_w_picpath110

Step15:输入要添加的主机IP(或者域名),输入用户名、密码,点击“下一步”

clip_p_w_picpath112

Step16:点击“是”

clip_p_w_picpath114

Step17:点击“下一步”

clip_p_w_picpath116

Step18:更换产品密钥,点击“下一步”

clip_p_w_picpath118

Step19:点击“下一步”

clip_p_w_picpath120

Step20:勾选“将此主机所有虚拟机置于根目录资源池中”,点击“下一步”

clip_p_w_picpath122

Step21:点击“完成”

5.Windows2008R2系统安装

clip_p_w_picpath082[1]

Step1:打开“VMwarevSphereClient”,输入ESXi主机的IP,点击“登录”

clip_p_w_picpath124

Step2:登录后,进入ESXi5.1管理界面。

clip_p_w_picpath126

Step3:右键选择“新建虚拟机”

clip_p_w_picpath128

Step4:选择“典型”,点击“下一步”

clip_p_w_picpath130

Step5:输入虚拟机名称“windows2008R2”,点击“下一步”

(其它选项,根据需要输入、设置相应的值即可)

clip_p_w_picpath132

Step6:虚拟机创建完成后,勾选“完成前编辑虚拟机设置”,点击完成。

clip_p_w_picpath134

Step7:右键新创建的虚拟机,选择“打开控制台”

clip_p_w_picpath136

Step8:点击”CD/DVD驱动器1”->选择“连接到本地磁盘上的ISO映象”->从本机选择“windows2008R2”镜像文件->(此处省略windows2008R2安装过程)

6.网络配置 6.1.开启vmotion

clip_p_w_picpath138

Step1:点击主机->选择“配置”菜单->选择“网络”->选择“属性选项”

clip_p_w_picpath140

Step2:单击“MangemetNET…”选项,点击下方“编辑”选项

clip_p_w_picpath142

Step3:勾选“vMotion”选项,启用vmotion

6.2.使用端口组

clip_p_w_picpath144

Step1:点击左侧列表中虚拟机,右键选择“编辑设置”

clip_p_w_picpath146

Step2:点击左侧“网络适配器”,右侧网络标签下拉框中,选择“VMNetwork”,点击“确定”

7.创建系统模板: 7.1.创建模板

clip_p_w_picpath148

Step1:点击需要创建模板的虚拟机,右键选择“模板”->“转换为模板”

7.2.从模板部署虚拟机

clip_p_w_picpath150

Step1:进入“虚拟机和模版”清单,点击系统模板,选择“从该模板布署虚拟机”

clip_p_w_picpath152

Step2:在弹出的向导中,输入名称“Windows2003”,点击“下一步”

clip_p_w_picpath154

Step3:虚拟磁盘格式,选择“与源格式相同”,选择存放路径为EMC存储,点击“下一步”

clip_p_w_picpath156

Step4:选择模板存储路径为群集,点击“下一步”

clip_p_w_picpath158

Step5:选择“不自定义”,点击“下一步”

clip_p_w_picpath160

Step6:点击“完成”

8.EMC存储配置 8.1.前期准备

l确保主机安装了JAVAJRE最新版本

l浏览器

clip_p_w_picpath162

打开IE浏览器,输入存储的管理地址,并选择对应的认证模式进行登录

IP:10.10.1.51IP:10.10.1.56

Username:*****Username:*****

Password:*****Password:******

8.2.配置storagepool

clip_p_w_picpath164

Step1:进入storage下storageconfig.

clip_p_w_picpath166

Step2:选择raidgroup选项卡,点击create创建raidgroup

clip_p_w_picpath168

Step3:填写RAID信息

lRAIDGroupID:需要创建的RaidGroup的次序号(默认从0开始)

lNumberofDisks:选择RaidGroup的磁盘数量(最多不超过16个)

lSupportedRAIDTypes:选择RaidGroup的类型(支持类型:Raid0/1/0+1/3/5/6)

lDiskSelection:磁盘选择的方式“auto”为自动,“manual”为手工

l磁盘数量及类型确认后系统会自动选择符合要求的磁盘(未使用)。如需手工选择的话,先选择“manual”,然后选择“select”选择对应的磁盘即可。

8.3.创建Lun

clip_p_w_picpath170

Step1:选择storage下的lun,点击create创建对应的lun

clip_p_w_picpath172

Step2:填写lun信息

lRAIDType:Lun对应的RaidGroup对应的Raid类型

lRAIDGroupforNewLun:RaidGroup的次序号

lLunID:需要创建的Lun的次序号

lDefaultOwner:Lun对应的宿主控制器(一个Lun同时只能受一个SP的管理)

lLunSize:需创建的Lun的大小

8.4.HBA卡在存储的注册状态

clip_p_w_picpath174

Step1:选择“host”菜单栏,进入“connectivitystatus”选项卡

clip_p_w_picpath176

Step2:查看状态

lInitiatorWWN:对应服务器HBA卡WWN号

lSP-port:服务器HBA卡对应存储SP的端口号

lFibreLoggedIn:光纤卡连接状态提示(YES=光纤通道正常,No=光纤通道有问题)

lRegistered:服务器HBA在存储注册状态(主机端安装agent软件可实现自动注册)

lServerName:HBA卡对应服务器的主机名(主机端安装agent软件可自动获取)

8.5.创建StorageGroup

clip_p_w_picpath178

Step1:选择storage下的storagegroup选项卡,点击create创建

clip_p_w_picpath180

Step2:在host选项卡中,选中左侧可用主机到右侧

clip_p_w_picpath182

Step3:HostID默认设置从0开始.在luns选项卡中,选择需要分配给host的lun并制定对应的hostid

9.VPLEXLocal实施 9.1.实施计划

序号

项目

内容

硬件安装

VPLEX上架、连线;设备初始化;

VPLEX实施准备

在交换机创建配置;

在后端存储创建MetaVolume所需LUN。

VPLEX实施

配置VPLEX。

9.2.VPLEXLocal管理IP配置

设备

Hostname

IP

Mask/Gateway

VPLEX

SCC-VPLEX

******

*

VNX5100

VNX5100-1

*

*

VNX5100

VNX5100-2

*

*

*

*

DS-300B

DS_300B_UP

*

*

DS-300B

DS_300B_DOWN

*

*

9.3.VPLEX的SANSwitch配置

Fabric1(DS300B_UP):

zone:VPLEX_1_DA_B0_VNX5100_1_SPA0

VPLEX_1_DA_B0;VNX5100_1_SPA0

zone:VPLEX_1_DA_B0_VNX5100_1_SPB0

VPLEX_1_DA_B0;VNX5100_1_SPB0

zone:VPLEX_1_DA_B0_vnx5100_2_spa0

VPLEX_1_DA_B0;vnx5100_2_spa0

zone:VPLEX_1_DA_B0_vnx5100_2_spb0

VPLEX_1_DA_B0;vnx5100_2_spb0

zone:VPLEX_1_DB_B0_VNX5100_1_SPA0

VPLEX_1_DB_B0;VNX5100_1_SPA0

zone:VPLEX_1_DB_B0_VNX5100_1_SPB0

VPLEX_1_DB_B0;VNX5100_1_SPB0

zone:VPLEX_1_DB_B0_vnx5100_2_spa0

VPLEX_1_DB_B0;vnx5100_2_spa0

zone:VPLEX_1_DB_B0_vnx5100_2_spb0

VPLEX_1_DB_B0;vnx5100_2_spb0

zone:scc_ha11,0;1,1;scc_ha1_1;vnx5100_2_spa0;vnx5100_2_spb0

alias:VNX5100_1_SPA0

1,1

alias:VNX5100_1_SPB0

1,0

alias:VPLEX_1_DA_B0

1,19

alias:VPLEX_1_DA_F0

1,18

alias:VPLEX_1_DB_B0

1,23

alias:VPLEX_1_DB_F0

1,22

alias:scc_ha1_1

1,10

alias:vnx5100_2_spa0

1,8

alias:vnx5100_2_spb0

1,9

Fabric2(DS300B_DOWN)

VPLEX_1_DA_B1_VNX5100_1_SPB1;

VPLEX_1_DA_B1_vnx5100_2_spa1;VPLEX_1_DA_B1_vnx5100_2_spb1;

VPLEX_1_DB_B1_VNX5100_1_SPA1;VPLEX_1_DB_B1_VNX5100_1_SPB1;

VPLEX_1_DB_B1_vnx5100_2_spa1;VPLEX_1_DB_B1_vnx5100_2_spb1

zone:EBS2_B11,1;1,7;vnx5100_2_spa1

zone:R710_A1_B1

1,0;1,1;1,2;vnx5100_2_spa1;vnx5100_2_spb1

zone:VPLEX_1_DA_B1_VNX5100_1_SPA1

VPLEX_1_DA_B1;VNX5100_1_SPA1

zone:VPLEX_1_DA_B1_VNX5100_1_SPB1

VPLEX_1_DA_B1;VNX5100_1_SPB1

zone:VPLEX_1_DA_B1_vnx5100_2_spa1

VPLEX_1_DA_B1;vnx5100_2_spa1

zone:VPLEX_1_DA_B1_vnx5100_2_spb1

VPLEX_1_DA_B1;vnx5100_2_spb1

zone:VPLEX_1_DB_B1_VNX5100_1_SPA1

VPLEX_1_DB_B1;VNX5100_1_SPA1

zone:VPLEX_1_DB_B1_VNX5100_1_SPB1

VPLEX_1_DB_B1;VNX5100_1_SPB1

zone:VPLEX_1_DB_B1_vnx5100_2_spa1

VPLEX_1_DB_B1;vnx5100_2_spa1

zone:VPLEX_1_DB_B1_vnx5100_2_spb1

VPLEX_1_DB_B1;vnx5100_2_spb1

alias:VNX5100_1_SPA1

1,0

alias:VNX5100_1_SPB1

1,1

alias:VPLEX_1_DA_B1

1,19

alias:VPLEX_1_DA_F1

1,18

alias:VPLEX_1_DB_B1

1,23

alias:VPLEX_1_DB_F1

1,22

1,10

alias:vnx5100_2_spa1

1,8

alias:vnx5100_2_spb1

1,9

9.4.创建MetaVolume

登录2台VNX5100的管理界面Unisphere,,选择Storage>LUNs,点击Create。

创建如下4个LUN:

Name

Storage

ID

StoragePool

UserCapacity

HostInformation

VPLEX_1_Meta_backup_1

VNX5100-1

601

DATABASEPOOLS

78GB

SCC-VPLEX

VPLEX_1_Meta_vol_1

VNX5100-1

600

DATABASEPOOLS

78GB

SCC-VPLEX

VPLEX_1_Metavol_Mirror

VNX5100-2

600

DATABASEPOOLS

78GB

SCC-VPLEX

VPLEX_1_Metavol_Backup_2

VNX5100-2

601

DATABASEPOOLS

78GB

SCC-VPLEX

各个LUN的UUID如下:

Name

UniqueID

VPLEX_1_Meta_backup_1

*****

VPLEX_1_Meta_vol_1

*****

VPLEX_1_Metavol_Mirror

****

VPLEX_1_Metavol_Backup_2

******

9.5.VPLEXLocal配置

clip_p_w_picpath184

在VPLEXLocal的配置过程中,有些命令需要在VPLEX管理服务器的命令行接口上运行,有些命令则需要在VPLEX引擎的命令行上运行,以下标志代表命令的运行场所:

Shell>:管理服务器的命令行接口

VPlexcli>:VPLEX引擎的命令行接口

1.确认实施准备工作已经完成,包括:

VPLEX和后端存储到光纤交换机的连接已完成;

光纤交换机的Zone配置已完成;

VPLEX所需的MetaVolume已经创建完毕。

2.设置管理服务器公用IP地址

设置个人电脑的网络地址为128.221.252.3/24,直接连接个人电脑的网络端口到管理服务器的ServicePort端口。

打开远程登录工具PuTTY,建立一个到管理服务器ServicePort128.221.252.2的SSH连接,确认SSH协议版本为2,点击Open连接到管理服务器,输入用户名(service)和密码(*****),登录到管理服务器:

clip_p_w_picpath186

更改管理服务器主机名:

Shell>#sudo/opt/emc/VPlex/tools/ipconfig/changehostname.py-nSCC-VPLEX

Shell>#exit

重新登录管理服务器,查看/etc/HOSTNAME文件内容,确认主机名更改成功:

Shell>#cat/etc/HOSTNAME

连接到VPLEX命令行接口,用户名为******,密码为********:

Shell>#vplexcli

clip_p_w_picpath188

设置管理服务器公用IP地址:

VPlexcli>#management-serverset-ip-i*********255.255.255.0-g*****eth3

VPlexcli>#ll/management-server/ports/eth3

clip_p_w_picpath190

3.检查VPLEX软件版本,确认符合版本控制要求,否则按照VPLEXConfigurationGuide里的步骤升级软件到要求版本:

VPlexcli>#configurationconnect-local-directors

VPlexcli>#ll/engines/**/directors

VPlexcli>#version

clip_p_w_picpath192

4.检查VPLEX健康状况:

VPlexcli>#exit

Shell>#VPlexPlatformHealthCheck

clip_p_w_picpath194

5.运行EZ-Setup配置向导,完成以下配置:

VPlexcli>#configurationsystem-setup

提示

选择

Continue?(yes/no)

yes

Whatwouldyouliketoconfigure?

1.ConfigureaVPLEXLocal(singlecluster).

2.ConfigureaVPLEXMetro(synchronous,2clusters).

3.ConfigureaVPLEXGeo(asynchronous,2clusters).

Selectyourconfigurationchoice.(1-3)

1

AreyousureyouwanttoconfigureaVPLEXLocal?(yes/no):

Yes

Wouldyouliketoconfiguretheloginbanner?(yes/no)[no]:

no

WouldyouliketoconfigureanauthenticationserviceprovidertoauthenticateVPLEXusers?(yes/no)[no]:

no

WouldyouliketoconfigurethisclustertosendeventnotificationstoEMC?(yes/no)[yes]:

no

WouldyouliketoconfigurethisclustertosendsystemreportstoEMC?(yes/no)[yes]:

no

WouldyouliketoconfiguretheclustertoruntheSNMPAgentService?(yes/no)[no]:

no

HowmanyyearsshouldtheCAcertificateremainvalidbeforeexpiring?EMCrecommends5years(maximumis5years).[5]:

5

Howmanyyearsshouldthehostcertificateremainvalidbeforeexpiring?EMCrecommends2years(maximumis2years).[2]:

2

Wouldyouliketorunthesetupprocessnow?(yes/no):

yes

Pleasecreateapassphrase(atleast8characters)fortheCertificateAuthorityKey.MakeanoteofthispassphraseasyouwillneedittoconfigureasecondclusterofaVPLEXLocalorGeo.

CertificateAuthoritypassphrase:

scc12345

Re-enterthepassphrasefortheCertificateAuthorityKey:

scc12345

Pleasecreateapassphrase(atleast8characters)fortheLocalHostCertificateKey.Makeanoteofthispassphraseasyouwillneeditlater.

HostCertificatepassphrase:

scc12345

Re-enterthepassphrasefortheCertificateKey:

scc12345

6.在后端存储分配MetaVolume给VPLEX

查看VPLEXcluster-1的后端端口WWN:

VPlexcli>#ll/engines/**/ports

clip_p_w_picpath196

根据各端口的WWN,在VNX5100按规划注册VPLEX的后端口,并分配MetaVolume给VPLEX。

7.继续运行EZ-Setup

VPlexcli>#configurationcontinue-system-setup

8.创建MetaVolume

获取适合创建MetaVolume的磁盘设备:

VPlexcli>#configurationshow-meta-volume-candidates

clip_p_w_picpath198

比较VPLEX识别到的磁盘设备的VPD名字与VNX上的LUN的UniqueID,确认两者对应关系:

clip_p_w_picpath200

按规划创建MetaVolume:

VPlexcli>#meta-volumecreate-nVPLEX_META-dVPD83T3:6006016008a02c001c56d62365fee211,VPD83T3:600601603221340024bce07667fee211

clip_p_w_picpath202

查看MetaVolume的状态,确认active属性列显示为true:

VPlexcli>#ll/clusters/cluster-1/system-volumes/vplex_meta

clip_p_w_picpath204

查看cluster的状态,确认clusterstatus和operational-status显示为ok:

VPlexcli>#clusterstatus

clip_p_w_picpath206

9.创建MetaVolumeBackup

获取适合创建MetaVolumeBackup的磁盘设备:

VPlexcli>#ll/clusters/cluster-1/storage-elements/storage-volumes

clip_p_w_picpath208

比较VPLEX识别到的磁盘设备的VPD名字与VNX的LUN的UniqueID,确认两者对应关系,按规划设置MetaVolume备份:

VPlexcli>#configurationmetadata-backup

clip_p_w_picpath210

设置本地时间0:15(UTC时间00:06)启动备份,MetaVolume的备份时间大约为10分钟

10.注册VPLEX

VPlexcli>#configurationregister-product

clip_p_w_picpath212

按提示输入联系人,地址等信息完成注册。

clip_p_w_picpath214

11.激活VPLEX前端口

VPlexcli>#configurationenable-front-end-ports

clip_p_w_picpath216

12.VPLEX健康检查

执行VPLEX健康检查,确认所有状态是OK,否则根据Warning或Error信息,修改不正确的配置。

VPlexcli>#health-check

clip_p_w_picpath218

至此,VPLEXLocal的安装配置已经完成,日常的操作(主机注册,存储空间分配等),建议在VPLEXUnishpere执行。

9.6.VPLEX用户管理

Vplex对用户授权管理的界面分为两个部分:ManagementServer、FibreChannelCOMSwitches。其中:

ManagementServer的默认用户如下:

用户

密码

权限

service

Mi@Dim7T

?Accesstothemanagementserverdesktop,VPlexcli,andUnisphereforVPLEXGUI

?Abilitytostartandstopmanagementserverservices

?Accesstomostfilesonthefilesystem

admin

teS6nAX2

?Abilitytocreate,modify,anddeleteVPLEXuseraccounts

?Accesstomanagementserverdesktop,VPlexcli,andGUI

?Abilitytostartandstopmanagementserverservices

*admin用户第一次cli登录使用需要修改掉默认密码。

SCC-VPLEX的admin用户密码为:

用户:admin

密码:*******************************

注意:

1.Service用户权限较高,是供EMC初始化或售后维护使用,不建议修改service的密码;

2.为了安全管理,建议用户尽量日常维护使用admin用户,并新建独立的监控(monitor)和操作(operator)用户;

3.如需修改用户密码,必须遵循Vplex密码策略:

a)至少14位,包含数字、大写、小写、特殊字符

b)不能是dictionarywords

c)离上一次修改至少1天才能作更改

d)每隔90天必须修改一次,从第75天开始弹出密码修改提示

如何增加、修改、解锁、删除用户:

1.增加用户:

以admin登陆vplexcli。

Vplexcli

VPlexcli:/>useradd–u

在弹出提示后输入用户名和密码,密码规则如上所述

2.修改用户密码:

以admin登陆vplexcli。

Vplexcli

VPlexcli:/>userpasswd–u

在弹出提示后输入旧密码、然后输入两次新密码,密码规则如上所述

3.用户解锁:

以admin登陆vplexcli。

Vplexcli

VPlexcli:/>userreset–u

在弹出提示后输入admin密码,然后输出两次新用户密码,密码规则如上所述

4.删除用户:

以admin登陆vplexcli。

Vplexcli

VPlexcli:/>userremove–u

在弹出提示后输入admin密码

9.7.登录VPLEXWeb图形管理界面

浏览器支持:

?英文版Windows:InternetExporter7或以上、Firefox3.5.5或以上

?中文版Windows:英文版的firefox3.5.x、Firefox3.6.x

?Adobeflashplayerv10.0.0或以上

10.VPLEX配置 10.1.配置storage加入到vplex

在需要进行虚拟化管理的storage加入vplex之前,先要划分了vplex后端接口和storage接口之间的zone,使得storage上面能看到vplex的后端接口的wwn.此时VPLEX相当于initiator,storage相当于target.从storage上面划分的lun要从其它主机上面完全断开,即delete以前配置的storagegroup,重新配置新的storagegroup,把Lun分给vplex识别到。

通过web方式连接到vplex,扫描识别新的lun到vplex

clip_p_w_picpath220

clip_p_w_picpath222

选择rediscoverarray

clip_p_w_picpath224

在vplex上完成识别新的lun,如上图所示中unclaimed的即为新扫描到的磁盘。

clip_p_w_picpath226

10.2.命令行claim新识别的lun

Vplex中claim一个lun相当于重先识别一下其它storeage分过来的Lun,使其置于vplex的管理之下,这个过程不会破坏Lun上已经存在的数据

VPlexcli:/>cd/clusters/cluster-1/storage-elements/storage-arrays/EMC-CLARiiON-CKM00111101040

VPlexcli:/clusters/cluster-1/storage-elements/storage-arrays/EMC-CLARiiON-CKM00111101040>storage-volumeclaim-dVPD83T3:6006016008a02c0000c64a158a10e311-nRAID5_SYSTEM_LINUX_DATA1

完成claim后的磁盘状态变为claimed,名字为上面命令行中起的RAID5_SYSTEM_LINUX_DATA1

clip_p_w_picpath228

10.3.创建extend

创建extend相当于VPLEX重新封装一下Storage上分过来的LUN,在封装原有的LUN上面有数据而不想破坏,这现在的LUN和以前的LUN一定要一样大,即最大化以前LUN的尺寸。

操作过程如下:

先进入extents的管理

clip_p_w_picpath230

选择create

clip_p_w_picpath232

把刚claimed的lun加入到右边,然后点击next下一步

clip_p_w_picpath234

(*说明:上面如不想破坏以前的数据一定要选上useMaximum)

clip_p_w_picpath236

Commit后即完成extend的创建过程。

10.4.创建device

设备的创建可以把现在加入到vplex的lun可以重先组织raid0,raid1,串联,以前保持原来lun的大小不变。如现在加入的lun是从多个不同的storage上分配过来的则可以完成在不同的storage之间进行mirror,以实现不同storage之间的容灾动态迁移等功能。

配置如下:

clip_p_w_picpath238

选择create

clip_p_w_picpath240

如想保持原来LUN上面的数据不破坏,选择1:1的进行封装。

clip_p_w_picpath242

选择第三步骤中创建的extents

clip_p_w_picpath244

选择自动创建虚拟卷

clip_p_w_picpath246

clip_p_w_picpath248clip_p_w_picpath250

Commit后即完成虚拟卷的配置

10.5.注册主机

clip_p_w_picpath252

clip_p_w_picpath254

clip_p_w_picpath256

10.6.创建storageview

Storageview相于vnx5100中的storagegroup。用来把主机,Lun,以及vplex的port关联起来,让特定的主机识别到特定的LUN。也相当于lunmasking功能。

clip_p_w_picpath258

选择创建:

clip_p_w_picpath260

把主机的hba卡加进去

clip_p_w_picpath262

clip_p_w_picpath264

选择LUN是通过vplex的哪些port映射出去。目前vplex只连了4个前端主机接口,所以只能看到4个正常的port,都加进去

clip_p_w_picpath266

clip_p_w_picpath268

选择要分给主要的lun设备

clip_p_w_picpath270

clip_p_w_picpath272clip_p_w_picpath274

clip_p_w_picpath276clip_p_w_picpath278

clip_p_w_picpath280

以上过程完成了主机对lun的分配。在主机上扫描磁即可以识别到新的磁盘

(注意:vplex模拟的是invista的磁盘。如是aix主机装powerpath多路径软件时,安装odm库时要选择invista的驱动)

10.7.创建mirror,实现不同storage之间的数据冗余

此过程相对比较简单,如vnx5100_1上面的lun通过vplex已经分给主机在正常使用中了。此时可以在vnx5100_2上再分配一个同样大小的lun给vplex,然后把vnx5100_2的lun镜像到vnx5100_1上去。完成同步后即实现了不同storage之间的数据冗余,保证了高可用性,坏掉其中一个storage对主机来讲都没有任何影响。

如有在线的数据进行Mirror时,建议用命令行方式做,不易出错坏数据。

以下面以vnx5100_2上划的2T(target)的盘,与vnx5100_1上2T(source,已经通过vplex分给主机在使用中)的进行mirror为例:

VPlexcli:/>storage-volumeclaim-dVPD83T3:6006016032213400200e333f9c10e311–nNEW_RAID5_SYSTEM_LINUX_DATA1

(此命令同前面一样,在vplex上claim一下vnx55001T的磁盘)

VPlexcli:/>deviceattach-mirror-ddevice_RAID5_SYSTEM_LINUX_DATA1_1-mextent_NEW_RAID5_SYSTEM_LINUX_DATA1_1

(此命令把vplex上已经在使用的磁盘device_RAID5_SYSTEM_LINUX_DATA1_1与新加入的磁盘进行mirror)

在mirror过程中查看rebuild的速度:

VPlexcli:/>rebuildstatus

clip_p_w_picpath282

clip_p_w_picpath284

11.DataDomain实施及配置 11.1.DataDoamin设备初始化 11.1.1.硬件初始化

DataDomain640硬件初始化步骤包括如下内容:

1.DataDomain640上架;

2.确保DataDomain640通电3小时后再进行配置(NVRAM需要充电3小时);

3.如果NVRAM充电没有3小时的后,系统将会自动关闭所有的功能(文件系统将会处于disable的状态);

4.DataDomain640连接可以采用RJ232进行连接,或者是直接连接显示器和键盘进行;

11.1.2.DDOS初始化

连接DataDomain640后,按照如下的步骤进行OS的初始化:

1.使用RJ232或者是直接接显示器和键盘,并登入DD640;

默认为的登录用户名是sysadmin;

初始密码是DataDomain机器的SN(可以在背面进行查看)

2.登录进行系统后运行configsetup进行配置。

注意:红色字体部分是需要进行输入和添加的部分

sysadmin@DD640#configsetup

LicensesConfiguration

ConfigureLicensesatthistime(yes|no)[no]:no

配置网络:

NetworkConfiguration

ConfigureNetworkatthistime(yes|no)[no]:yes

Hostname

Enterthehostnameforthissystem(fully-qualifieddomainname)

[DD640_mindray.localdomain]:DD640.localdomain

Domainname

EnteryourDNSdomainname

[localdomain]:

Ethernetporteth0a

EnableEthernetporteth0a(yes|no|?)[yes]:yes

UseDHCPonEthernetporteth0a(yes|no|?)[no]:no

EntertheIPaddressforeth0a

[10.10.10.1]:******

Enterthenetmaskforeth0a

[255.0.0.0]:255.255.255.0

Ethernetporteth0b

EnableEthernetporteth0b(yes|no|?)[yes]:yes

UseDHCPonEthernetporteth0b(yes|no|?)[no]:no

EntertheIPaddressforeth0b

[10.10.10.1]:******

Enterthenetmaskforeth0b

[255.0.0.0]:255.255.255.0

DefaultGateway

EnterthedefaultgatewayIPaddress

:10.10.1.254

DNSServers

EntertheDNSServerlist(zero,one,twoorthreeIPaddresses)

:直接回车

PendingNetworkSettings

HostnameDD640.localdomain

Domainnamelocaldomain

DefaultGateway10.10.1.254

DNSServerList

PortEnabledCableDHCPIPAddressNetmask

--------------------------------------------

eth0ayesnono1****255.255.0.0

eth0ayesnono****255.255.0.0

--------------------------------------------

***NoconnectiononconfiguredEthernetport

Doyouwanttosavethesesettings(Save|Cancel|Retry):Save(保存网络配置)

FilesystemConfiguration

ConfigureFilesystematthistime(yes|no)[no]:yes

Globalcompressiontype

Willthisrestorerreplicateto/fromrestorerswiththeoldglobalcompressiontype"1"?(yes|no|?)[no]:yes

Changetheglobalcompressiontypeofthisfilesytemfornewdatato"1"?(yes|no)[yes]:yes

Localcompressiontype

Whatlocalcompressiontypewillthisfilesystemuse?(none|lz|gz|gzfast)[lz]:建议使用lz模式进行压缩

Markertype

Whatmarkertypewillthisfilesystemuse?(none|nw1|cv1|tsm1|tsm2|eti1|hpdp1|besr1|***t1|ism1|auto)[auto]:直接回车

PendingFilesystemSettings

GlobalCompressionType1

LocalCompressionTypelz

Markertypeauto

Doyouwanttosavethesesettings(Save|Cancel|Retry):Save

SystemConfiguration

ConfigureSystematthistime(yes|no)[no]:yes

AdminHost

Enterahostnameforadministrativeaccesstotherestorer

[bakserver.localdomain]:

AdminEmail

Enteranemailaddressorgroupaliasthatwillreceiveemail

fromtherestorer.Theaddressisalsousedasthe'From'

addressinallemailsentbytherestorer.

:[email protected]

SystemLocation

Enteraphysicallocation,tobetteridentifythissystem.

[unspecified]:直接回车

MailServer

Enterthehostnameofamail(SMTP)servertorelayemailalerts.

[mail]:

Timezone

Enteryourtimezonename.

[Asia/Shanghai]:直接回车

ConfigureNTP

EnableNetworkTimeService?(yes|no)[yes]:no

NTPserver:

PendingSystemSettings

AdminhostDD640.localdomain

Adminemail

Systemlocationunspecified

SMTPservermail

TimezoneAsia/Shanghai

Doyouwanttosavethesesettings(Save|Cancel|Retry):Save

CIFSConfiguration

ConfigureCIFSatthistime(yes|no)[no]:

NFSConfiguration

ConfigureNFSatthistime(yes|no)[no]:

Configurationcomplete.

配置完成。

3.启动文件系统(可选步骤),(需要在NVRAM充电3小时后)

采用ssh登陆DD640系统。

sysadmin@P-DD640-1_mindray#filesysstatus

如果显示为disable

请启用文件系统:

sysadmin@P-DD640-1_mindray#filesysstart

11.2.DataDomainCIFS配置 11.2.1.登录DD640

1.使用IE登陆DD640

如DD640设置的IP为*****,就在IE中输入http://****在出现的界面中输入用户名和密码:用户名:sysadmin,密码:****

clip_p_w_picpath286

2.登陆以后,将会看见主界面:

clip_p_w_picpath288

11.2.2.启动CIFS服务

1.选择“datamanagment”à“CIFS”:

clip_p_w_picpath290

“CIFSStatus”-->Enable,激活CIFSService

2配置CIFS服务

2.1建立一个mtree

clip_p_w_picpath292

2.2建立cifs共享目录

clip_p_w_picpath294

clip_p_w_picpath296

2.3添加主机的map地址

clip_p_w_picpath298

clip_p_w_picpath300

2.4建立用户

clip_p_w_picpath302

clip_p_w_picpath304

2.4挂载CIFS

clip_p_w_picpath306

clip_p_w_picpath308

3管理DD

后续有DNS,Mailserver需要加入的话可以用图形界面来做

clip_p_w_picpath310

3.1修改网络

clip_p_w_picpath312

3.2添加DNS地址

clip_p_w_picpath314

3.3添加需要收邮件的emai地址

clip_p_w_picpath316

添加邮件服务器地址

clip_p_w_picpath318

12.AnywhereUSB配置 12.1.初始化配置

Step1:使用IE浏览器访问web:*****。用户名:*****,密码:*****

clip_p_w_picpath320

Step2:修改IP地址

clip_p_w_picpath322

Step3:修改登录密码

clip_p_w_picpath324

Step4:USB分组,如下述分组即可实现,单个服务器识别单个USBKEY(修改分组后需要重启才有效)

12.2.使用方法

Step1:安装对应的client软件:AnywhereUSB64Bit.exe/AnywhereUSB32Bit.exe

clip_p_w_picpath326

Step2:添加连接列表

clip_p_w_picpath328

Step3:添加AnywhereUSB的IP地址及组号码(组号码与USB接的端口一致)



【本文地址】